Prepare for UPSC Indian Engineering Services (IES/ESE) with official previous years' questions, detailed derivations, phasor analysis, and circuit solutions across Electrical Machines, Power Systems, Control Systems, Power Electronics, Network Theory, and Analog & Digital Circuits.
Marking pattern: +2.00 positive, -0.66 negative (Official UPSC ESE 1/3rd Negative Marking Scheme; 150 Questions, 300 Marks).
When a separately excited d.c. motor is to be controlled from a three-phase supply fed from controlled rectifier in only first quadrant, which one of the following converters is used to serve the purpose?
In case of a squirrel-cage induction motor using three-phase bridge inverter, which one of the following statements is correct for speed control?
The following characteristics are drawn for salient-pole synchronous motor:
The curve B denotes
While finding various factors of single-phase diode rectifiers, the transformer utilization factor of a half-wave rectifier is
The positive sequence impedance component of three unequal impedances $Z_{a}$, $Z_{b}$ and $Z_{c}$ is
Which one of the following wiring systems is commonly used for light/fan load in domestic and commercial buildings?
Which one of the following is not an advantage in using bundle conductors?
Which one of the following is not a method of voltage control in power systems?
An inductance of 800 $\mu$H connects two sections of a transmission line each having a surge impedance of 200 $\Omega$. A 500 kV, 2 $\mu$sec rectangular surge travels along the line towards the inductance. What is the maximum value of the transmitted wave?
The faults on power systems are analyzed easily by making use of
Which one of the following is not a basic functional characteristic of a protective relay?
In a system of 132 kV, the line-to-ground capacitance is 0.01 $\mu$F and the inductance is 4 H. What is the voltage appearing across the pole of a circuit breaker if the instantaneous value of magnetizing current of 5 A is interrupted?
Which one of the following tests does not come under the testing types of circuit breaker?
In a power system, the maximum power can be transferred from one end to another end when the reactance of the line is
A 50 Hz, four-pole turbogenerator rated at 30 MVA, 13.2 kV has an inertia constant of $H=9.0\text{ kW-sec/kVA}$. What is the KE stored in the rotor at synchronous speed?
Which one of the following is not an example of renewable energy?
There are additional losses that arise from the non-uniform current distribution in the conductors and the core losses generated in the iron due to the distortion of the magnetic flux distribution from the load currents. Such losses are known as
If the magnetic core has a constant permeability by making air as media for a coil current and the resultant flux linkage, then
The structure of d.c. commutator machine is generally designed with
The steady-state external performance characteristic of a d.c. generator has the relationship between
A 250 V, 50 kW, short-shunt compound d.c. generator has the following data: armature resistance = 0.05 $\Omega$, series field resistance = 0.05 $\Omega$, shunt field resistance = 130 $\Omega$ and 2 V is the total brush contact drop. What is the value of the total current supplied by the generator?
In generating mode, an induction machine operates as a generator with a shaft speed which is greater than the synchronous speed, if the slip is
A three-phase, 60 Hz, 25 HP, wye-connected induction motor operates at a shaft speed of almost 1800 r.p.m. at no load and 1650 r.p.m. at full load. The number of poles of the motor is
A three-phase, 13.2 kV, 60 Hz, 50 MVA, wye-connected cylindrical rotor synchronous generator has an armature reactance of 2.19 $\Omega$ per phase. The leakage reactance is 0.137 times the armature reactance. The armature resistance is small enough to be negligible. Also ignore the saturation. Assume that the generator delivers full-load current at the rated voltage and 0.8 lagging power factor. The synchronous reactance per phase is
For the commutated d.c. machine stator, it has riveted poles and the ends of the poles are called