Prepare for UPSC Indian Engineering Services (IES/ESE) with official previous years' questions, detailed derivations, phasor analysis, and circuit solutions across Electrical Machines, Power Systems, Control Systems, Power Electronics, Network Theory, and Analog & Digital Circuits.
Marking pattern: +2.00 positive, -0.66 negative (Official UPSC ESE 1/3rd Negative Marking Scheme; 150 Questions, 300 Marks).
Consider the following table wherein three typical acceleration input signals are fed to various system types where 'R' represents the amplitude of the input (note the situation of acceleration input) and 'K' is the open-loop gain of the time constant type. What are the steady-state errors in place of A, B and C respectively in the table?
| System type | Typical input signal | ||
|---|---|---|---|
| Step $$x(t)=R$$ | Ramp $$x(t)=Rt$$ | Acceleration $$x(t)=\frac{R}{2}t^{2}$$ | |
| 0 | $$\frac{R}{1+K}$$ | $$\infty$$ | A |
| I | 0 (zero) | B | $$\infty$$ |
| II | C | 0 (zero) | $$\frac{R}{K}$$ |
Which one of the following is not a method to reduce steady-state error of a system?
Consider the following statements related to root locus:
Which of the above statements are correct?
Consider the following visualizing lead compensation representation frequency versus gain crossover frequency[cite: 16]:
Which of the above curves is/are a compensator?[cite: 16]
Isolating transformers are commonly used in many types of electric circuits for the purpose of[cite: 16]
When there is no ferromagnetic material but only air present in between the coils, such a transformer is called[cite: 16]
The objectionable audible humming sound in the core of the transformer due to magnetostriction is minimized by[cite: 16]
The ideal two-winding transformer primary and secondary windings has $N_{1}=100$ turns and $N_{2}=200$ turns with a mutual coupling flux described by the parabolic function $\phi_{m}(t)=-0.05(t^{2}-2t)\text{ Wb}$. The primary terminal voltage is[cite: 16]
A 345-kV transmission line feeds a distribution substation that in turn has radial feeds to a 4160/2400-V, four-wire distribution network and the turns ratio of the $\Delta\text{-Y}$ connected 100-MVA transformer in this substation. Its line current ($I_{L1}$) at $\Delta$ side is[cite: 16]
A four-pole lap-wound DC machine armature has 54 slots with single-turn coils. How many armature conductors are required if there are two coil sides per slot?[cite: 16]
The magnetic cores of large transformers are built in stepped cores to
An autotransformer has an advantage over the equivalent two-winding transformer, which is
The stator and rotor slots of an asynchronous motor are designed to traverse the axial length of the magnetic core at an angle from the true axial direction. The average value of the mmf wave over the axial length of the magnetic core is
A 4-pole, 50-Hz, three-phase asynchronous motor is operating at a shaft speed of 1750 rpm. What is the speed of the stator air gap mmf wave?
Prior to placing a three-phase, Y-connected synchronous generator in service on the Y-connected electric utility grid, three lamps are connected across the open contactors served as indicators to assure synchronization conditions if the lamps will blink OFF and ON which indicates
A primitive stepper motor and its digital driver circuit is furnished with a train of f pulses per second, that the input of the controller is divided so that the output is sent in sequence to one phase winding at a time with 2p as the number of phases and k number of teeth. Then the rotor angular motion per pulse is a step of
Which one of the following statements is not correct?
For economic size the ratio of outer diameter to the conductor diameter should be 'e'. What is the economic overall diameter of a 1-core cable metal sheathed for a working voltage of 85 kV if the dielectric strength of the insulating material is 65 kV/cm?
When impedance is being calculated for an alternator, which measurement of parameter requires the series connection of windings in stator windings?
What is the percentage increase of busbar voltage required to compensate for the reactance drop when the feeder having a reactance of 5% carries a full load current at a p.f. 0.8 lagging?
The overcurrent relays are categorized by obtaining their characteristics as under:
The curve (b) in the characteristics is pertaining to which category of current relay?
Consider the following statements:
Which of the above statements is/are not correct?
Consider the table below for different types of buses where each set may consist of any parameters 'V' is voltage magnitude, 'P' is real power injection, 'Q' is reactive power and '$\delta$' is phase angle.
| Bus type | Set of quantities to be specified for bus | Set of quantities to be obtained for bus |
|---|---|---|
| Load bus | Set A | Set D |
| Slack bus | Set B | Set E |
| Generator bus | Set C | Set F |
Select the correct answer using the above table:
While the load flow equations are nonlinear and they are solved by using Gauss-Seidel Iterative Method by including PV buses, what would be the reason for the violation of reactive power limit?
Consider a system consisting of a synchronous machine connected to an infinite bus bar. The below power angle curve is obtained using equal area criterion when sudden increase in mechanical load on that motor occurs[cite: 18]:
| Point | Rotor Angle | Curve Location | Power Level ($P_e$) |
|---|---|---|---|
| $$a$$ | $$\delta_0$$ | On sinusoidal curve $$P_e = P_m\sin\delta$$ | $$P_0$$ (Initial equilibrium) |
| $$b$$ | $$\delta_s$$ | On sinusoidal curve $$P_e = P_m\sin\delta$$ | $$P_s$$ (New load demand) |
| $$c$$ | $$\delta_m$$ | On sinusoidal curve $$P_e = P_m\sin\delta$$ | $$P_e(\delta_m)$$ (Maximum swing angle) |
What is the condition of power at point 'b' if $P_e$ is electromagnetic power and $P_s$ is shaft power?