Prepare for UPSC Indian Engineering Services (IES/ESE) with verified solutions across Analog & Digital Communications, VLSI & Semiconductor Devices, Signals & Systems, Electromagnetics & Antennas, Microwave Engineering, Control Systems, Computer Organization, and Network Theory.
Marking pattern: +2.00 positive, -0.66 negative (Official UPSC ESE 1/3rd Negative Marking Scheme; 150 Questions, 300 Marks).
The critical fiber length of the fiber-reinforced composite ranges between
Match the following:
| List-I (Material) | List-II (Magnetism) |
|---|---|
| P. Silicon | 1. Ferromagnetism |
| Q. Molybdenum | 2. Diamagnetism |
| R. Cobalt | 3. Paramagnetism |
Select the correct answer using the code given below:
The cross-correlation of two finite length sequences $x(n) = \{1, 2, 1, 1\}$ and $y(n) = \{1, 1, 2, 1\}$ is
Consider the following relations of continuous time unit impulse function:
1. $\int_{-\infty}^{+\infty} x(t)\delta(t)dt = x(0) = 0\text{ (zero)}$
2. $\delta(t) = \delta(-t)$
3. $\delta(at) = \frac{1}{|a|}\delta(t)$
Which of the above relations is/are correct?
Consider the following statements:
1. Impulse response $h_{1}(n) = 3^{n}u(n)$ indicates the system is non-causal system.
2. Impulse response $h_{2}(n) = \cos\left(\frac{n\pi}{2}\right)$ indicates the system is causal system.
3. Impulse response $h_{3}(n) = e^{-5|n|}$ indicates the system is causal system.
Which of the above statements is/are not correct?
The system represented by $5s^{6}+8s^{5}+12s^{4}+20s^{3}+100s^{2}+150s+200=0$ is
For the unity feedback system given by $G(s)=\frac{K}{s(s+1)(s+2)}$, the range of K for stability is
What are the breakaway points of the root locus of a unity feedback system with open loop transfer function $G(s)=\frac{K(s+2)}{(s+1)^{2}}$?
Consider the following statements regarding the Bode plot for the type-2 system having transfer function of the form:
$$G(j\omega)=\frac{K}{(j\omega)^{2}(1+j\omega T)}$$
1. The intercept of the low frequency slope of 40 dB/decade (or its extension) with the 0 dB axis occurs at a frequency $\omega_{x}$, where $\omega_{x}=K$.
2. The value on the low frequency slope of 40 dB/decade (or its extension) at the frequency $\omega=1$, is equal to 40 log (K).
3. The gain K is the static ramp error coefficient.
Which of the above statements is/are not correct?
Consider the following statements:
1. Gain margin is used to indicate the proximity of the intersection of the negative real axis made by the polar plot of $G(j\omega)H(j\omega)$ to the $(-1+j)$ point.
2. Phase crossover point is the point in the $G(j\omega)$ plane at which the polar $G(j\omega)H(j\omega)$ plot intersects the positive real axis.
3. The phase crossover frequency is the frequency at the phase crossover point or where angle $\{G(j\omega)H(j\omega)\}=180^{\circ}$.
Which of the above statements is/are not correct?
If the open loop transfer function of a servo system with unity feedback is $G(s)=\frac{10}{s(1+0\cdot1s)}$, then the acceleration, velocity and position error constants are respectively
A feedback system has an open loop transfer function of $G(s)H(s)=\frac{K(1-s)}{s(s^{2}+5s+9)}$. The maximum value of K for the closed loop system to be stable is
A unity feedback system is characterized by an open-loop transfer function $G(s)=\frac{K}{s(s+10)}$. If the damping ratio is 0.5, then the time to peak overshoot for the unit step input is
Consider the following statements:
1. Rise time for the underdamped system is the time required for the response to rise from 5% to 95% of its final value.
2. The amount of maximum overshoot directly indicates the relative stability of the system.
3. Settling time is the time required for the response to reach and maintain within a specified tolerance band, i.e. either 3% or 6% of the final value.
Which of the above statements are not correct?
Consider the following statements:
1. In PD controllers, derivative action provides the counterbalancing effect of rapidly changing disturbances, which does not take care of the offset.
2. In PI controllers, proportionality constant provides simplicity, reliability, directness, etc.
3. PI systems have some oscillatory effect.
Which of the above statements are correct?
The crystal structure of Titanium metal is
Manganese oxide (MnO) is a
Consider the following statements regarding measurement system:
1. In the case of suspended coil permanent magnet moving coil (PMMC) instruments, the release of internal strain of the suspension wire causes drift of the zero-setting.
2. Creep of a transducer is usually defined as the change of output with time following a step increase in the input from one value to another.
3. Even above the threshold input, an instrument needs a minimum increment in the input to produce a perceptible output. This minimum necessary increment is called the resolution of the instrument.
Which of the above statements is/are correct?
Dead-zone in a pyrometer is 0.125% of the span. The instrument is calibrated from $800^{\circ}\text{C}$ to $1800^{\circ}\text{C}.$ What is the value of temperature below which no change can be detected?
Consider the following statements regarding measurement system:
1. If a known voltage of 200 V is being measured by a voltmeter and the successive readings are 204, 205, 203, 203 and 205 volts, then the accuracy is about 1.25%.
2. If 'a' denotes accuracy, 'p' denotes the precision and 'c' denotes the calibration error, then $a=p+c$.
3. Though the instrument is showing the correct value, the precision of the measurement depends upon the number of significant figures to which the observer can read the value.
Which of the above statements is/are not correct?
Consider the following statements regarding wet and dry bulb Hygrometer:
1. Ubiquitous hygrometer consists of two mercury-in-glass thermometers, the bulb of one of which is covered with a wick or muslin.
2. Wick or muslin, in turn, is always kept moist by dipping both its ends into water contained in a small vessel.
3. Continuous evaporation of water from the surface of the wet bulb keeps its temperature lower than that of the dry bulb.
Which of the above statements is/are not correct?
Consider the following statements regarding capacitive hygrometer:
1. It is suitable for measuring moisture content in many gases including hydrocarbons.
2. Being a capacitor, it can be easily incorporated in microprocessor-based electronic instrumentation.
3. It cannot be used to measure moisture content in polar materials such as alcohols.
Which of the above statements is/are correct?
What is the output of a successive approximation type 8-bit ADC if the input is 491 mV and the reference is 512 mV?
What is the percentage error in the measurement of kinetic energy of a body if the percentage error in the measurement of mass and speed is 2% and 3% respectively?
A mass of 10 kg is measured with an instrument and the readings are normally distributed with respect to the mean of 10 kg. Given that
$$\frac{2}{\sqrt{2\pi}}\int_{0}^{0\cdot84}\exp\left(\frac{-\eta^{2}}{2}\right)d\eta=0\cdot6$$
and 60 percent of the recordings are found to be within 0.05 kg from the mean. The standard deviation of the data is